Scenario 4 - Controller Version Update - Workflow Ready Signal#

Overview#

This scenario shows how to use the Defined in Workflow Detector to let the Controller workflow own the readiness decision. Instead of time windows or entity states, the IoT developer embeds ready logic directly in the workflow so that the update is triggered exactly when the equipment signals it is safe, without requiring operators to manage states or time windows.

In this example, the cookie factory's packing controller is upgraded from A/3 to A/4 across two packing lines, each upgrading independently as its workflow signals a safe state during a shift-change window.

When to Use#

  • Readiness owned by the workflow - when the IoT developer has embedded custom readiness logic in the Controller workflow and wants it to drive the maintenance trigger directly, rather than relying on MES states or time windows configured by operators.
  • Equipment conditions not visible to MES - when readiness depends on internal equipment state (sensor values, recipe progress, multi-step handshakes) that only the controller workflow can evaluate.
  • Complement to other detectors - use EntityStateInList when operators own readiness via Resource states; NoMaterialsOnResource when readiness is derived from Material tracking; DefinedInWorkflow when the IoT developer owns the readiness signal in code.

Example#

The cookie factory is upgrading its packing lines from PackingController A/3 to A/4. The update is not tied to a fixed maintenance window. Each packing cell upgrades independently when its production workflow signals that the line is at a safe stopping point between jobs. Shift-change Pre-Conditions ensure upgrades only happen during handover windows, and a 15-minute ready delay guards against transient pauses.

  • Resources: ASA Packer-01, ASA Packer-02.
  • Controller: PackingController.
  • Current version: revision A, version 3.
  • Target version: revision A, version 4.
graph LR
    subgraph current["PackingController A/3 (current)"]
        P1[Packer-01]
        P2[Packer-02]
    end
    W["Workflow\nready signal"] -->|DefinedInWorkflow| P1 & P2
    P1 -->|UpdateControllerVersion| P1T[Packer-01]
    P2 -->|UpdateControllerVersion| P2T[Packer-02]
    subgraph target["PackingController A/4 (target)"]
        P1T
        P2T
    end

Prerequisites#

Before creating the Definition, confirm the following:

  • Load the Scenario 4 automation master data into MES, it creates the PackingController [A.3] and PackingController [A.4] Controller definitions, packing-manager record, and both packer instances (master data package: 01-automation-masterdata.json).
  • All target instances are currently running PackingController revision A, version 3.
  • The shipped PackingController [A.3] sample installs the File Raw driver, but you must still implement or adapt workflow logic that sets and clears the DefinedInWorkflow ready signal for each instance before enabling the Definition.
  • MES Configuration Entries under /Cmf/Tutorials/AutomationScheduleAction/Scenario4/IoHealthy/{resourceName} are set to true for the Resources you expect to finish with ProcessedSuccess. The sample DEE defaults missing entries to false, which results in ValidationFailed.
  • Notification templates ASA PreAction Template, ASA Success Template, ASA Failure Template, and ASA Ignored Template exist in MES if you intend to use notifications.
  • DEE action ASA_Scenario4_ValidatePackerIo is created and deployed in MES before enabling the Definition (see How To: Create or Import a DEE Action).

Configuration#

Why This Pattern#

This Definition uses the following combination of components:

Component Type Purpose
Context AutomationController Discovers all instances currently running the source controller version (A/3).
Pre-Conditions AllowedWeekdays + AllowedTimeWindow Restricts upgrades to shift-change windows when lines are between production runs.
Detector DefinedInWorkflow Delegates the readiness decision to the controller workflow.
Acceptance Gate ReadyDelay Enforces a stability period after the workflow signals ready, preventing execution on transient transitions.
Action UpdateControllerVersion Stops the current runtime, removes it, and starts a new runtime with revision A, version 4.
Post Action Validation MaxStartupTime + CustomDeeAction Confirms the new runtime starts within the timeout and passes an I/O check.

Table 1: Scenario 4 Component Design

Create the Definition#

Open Automation Scheduled Action and select Create (see Create Definition). The wizard has four tabs.

Tab 1 - General Data#

Start by filling in the general definition fields.

  • Give it a name like CF_Update_Packaging_Controller_A4 and a description that captures its purpose (for example, "Upgrade packing controller from A/3 to A/4 when workflow signals safe state.").
  • Set Is Enabled to Disabled for now.
  • Set Validity to 5 days. This covers a full work week of shift windows. Adjust if your rollout window is shorter or longer.

For Context, select Automation Controller, enter PackingController as the controller:

  • Set Revision to A and Version to 3. This targets all instances currently running PackingController A/3 - one task per instance.

For the Detector, select Defined in Workflow. The workflow must signal readiness for this detector to return true. If the workflow does not implement this signal path, tasks will remain at SkippedNotReady until they expire.

For the Action, select Update Controller Version:

  • Set Revision to A and Version to 4.

Optionally, configure notification templates to be alerted at key moments:

Event Template
Pre-Action ASA PreAction Template
Success ASA Success Template
Failure ASA Failure Template
Ignored ASA Ignored Template

Table 2: Scenario 4 Notification Templates

Tab 2 - Pre-Conditions#

Select twice to add the following pre-conditions in this order:

1. Allowed Weekdays - Set the weekdays to Monday through Friday.

2. Allowed Time Window - Add three windows: 05:00–06:30, 13:00–14:00, and 21:00–22:00. These correspond to the shift-change windows in UTC. All times are evaluated in UTC, so convert your shift-change windows before entering them here.

Tab 3 - Acceptance Gates#

Select and select Ready Delay. Set the delay to 900 seconds. The workflow must signal ready for 15 consecutive minutes before the upgrade runs. This prevents triggering on a transient workflow state during a brief pause between jobs.

Tab 4 - Post-Action Validations#

Select twice to add the following validations in this order:

1. Max Startup Time - Set the timeout to 420 seconds. This waits up to 7 minutes for the new runtime to reach a running state.

2. DEE Action - Enter ASA_Scenario4_ValidatePackerIo as the action. This checks I/O connectivity after the instance starts.

Verify tasks before enabling

Click Save with Is Enabled set to Disabled. The system immediately resolves the context and creates one task per target instance.

Before enabling, open Automation Scheduled Action Tasks and confirm:

  • All expected targets appear in the task list.
  • No unexpected targets are included.

Once the task list is correct, enable the Definition from the top ribbon (see Enable / Disable Definition).

How It Works at Runtime#

After you enable the Definition, the system processes each task on every polling pass as follows:

  1. Context discovers all instances currently running PackingController A/3 and creates one task per instance.
  2. Weekday and time-window Pre-Conditions are checked against current UTC time. Tasks are skipped outside the allowed shift-change windows.
  3. The Detector queries the controller workflow whether this instance has signaled ready.
  4. The ReadyDelay Acceptance Gate confirms the workflow has maintained the ready signal for at least 15 minutes.
  5. The Action stops the current A/3 runtime and starts a new runtime with A/4.
  6. MaxStartupTime waits up to 7 minutes for the new runtime to reach a running state.
  7. ASA_Scenario4_ValidatePackerIo confirms I/O connectivity after startup.
  8. The task is finalized with outcome and notifications are sent.
flowchart TD
    A([Task per Packer instance]) --> B{"Shift window?<br/>Mon-Fri<br/>05:00-06:30<br/>13:00-14:00<br/>21:00-22:00"}
    B -- No --> S1([SkippedPreConditionFailed])
    B -- Yes --> C{"Workflow signals<br/>ready?"}
    C -- No --> S2([SkippedNotReady])
    C -- Yes --> D{"Stable 15+ min?"}
    D -- No --> S3([SkippedGateFailed])
    D -- Yes --> E["UpdateControllerVersion<br/>A/3 → A/4"]
    E --> NOP{"Already on<br/>A/4?"}
    NOP -- Yes --> IGN([IgnoredNoOp])
    NOP -- No --> F{"Running within<br/>420 s?"}
    F -- No --> FAIL1([ValidationFailed])
    F -- Yes --> G{"ASA_Scenario4_ValidatePackerIo<br/>passes?"}
    G -- No --> FAIL2([ValidationFailed])
    G -- Yes --> OK([ProcessedSuccess])

Expected Task Outcomes#

LastOutcome State Meaning
ProcessedSuccess Processed Controller upgraded and both validations passed.
IgnoredNoOp Ignored Instance was already running A/4 - no change needed.
ActionFailed Failed Runtime replacement failed. Check Manager capacity and Controller definition availability.
ValidationFailed Failed Runtime started but did not reach running state within 420 seconds, or the I/O check failed.
SkippedPreConditionFailed (task stays active) Current UTC time or weekday is outside the allowed shift-change windows.
SkippedNotReady (task stays active) Workflow has not signaled ready for this instance.
SkippedGateFailed (task stays active) Workflow signaled ready but has not sustained that state for 15 minutes yet.

Table 3: Scenario 4 Task Outcomes

Simulating This Scenario#

Confirm the Scenario 4 master data is loaded and both packer instances are running on packing-manager. This scenario uses DefinedInWorkflow as the Detector, so the Controller workflow must raise the ready signal explicitly.

The shipped sample master data does not include the final workflow logic that toggles DefinedInWorkflow for you. A simple demo pattern is to add a File Raw Driver step that watches a per-resource directory and sets the flag when a file named ready.signal appears. If you implement that pattern, you can drive readiness from the filesystem without redeploying code between test runs.

One simple directory convention for that demo workflow is:

C:\simulation\cookie-factory\{resource-name}\

To Trigger Processing for One Resource#

  1. On the machine running packing-manager, navigate to C:\simulation\cookie-factory\ASA Packer-01\.
  2. Create an empty file named ready.signal in that directory.
  3. Ensure /Cmf/Tutorials/AutomationScheduleAction/Scenario4/IoHealthy/ASA Packer-01 is set to true, otherwise the sample Post Action Validation ends in ValidationFailed.
  4. The File Raw Driver detects the new file, fires the workflow event, and the workflow sets the DefinedInWorkflow ready flag to true.
  5. Open Automation Scheduled Action Tasks and confirm IsReady becomes true for the ASA Packer-01 task.
  6. Wait 15 minutes. The ReadyDelay gate passes and the task executes UpdateControllerVersion from A/3 to A/4.
  7. Confirm the instance is now running PackingController A/4 in the Automation Controller Instance record.
  8. The task transitions to ProcessedSuccess.

Repeat steps 1–8 for ASA Packer-02. Each resource is processed independently.

To Observe the Gate Countdown#

Open the task and watch ReadyStateChangedAt. The Acceptance Gate requires this timestamp to be at least 15 minutes in the past before the action runs. Delete ready.signal before the Acceptance Gate passes. ReadyStateChangedAt resets and the countdown restarts from zero when the file is recreated.

To Demonstrate the Gate Reset#

  1. Create ready.signal for ASA Packer-01.
  2. After 10 minutes, delete the file.
  3. Confirm IsReady drops to false and ReadyStateChangedAt resets.
  4. Recreate the file and the 15-minute countdown starts over.

To Observe the Ignored Outcome#

Before enabling the Definition, manually update one instance to PackingController A/4 directly from the Automation Controller Instance record. Enable the Definition and the task for that instance transitions immediately to IgnoredNoOp because the target is already in the desired state.

To Reset and Repeat#

  1. Delete ready.signal from the Resource directory if present.
  2. Revert the instance back to PackingController A/3 from the Automation Controller Instance record.
  3. Create a new Definition (the original tasks are in a terminal state and will not re-evaluate).

Troubleshooting#

IsReady Does Not Become True After Creating ready.signal#

If IsReady stays false after creating the file, check:

  1. The File Raw Driver is running and watching the correct directory path for the target resource.
  2. The workflow step that handles the file event and sets the DefinedInWorkflow flag is reachable from the current instance state.
  3. The manager console shows no workflow errors for that instance.

UpdateControllerVersion Requires the Same Controller Lineage#