Automatic Process Data Collection#
Overview#
This feature enables Automatic Process Data Collection by parsing equipment events.
Currently supported events:
- UnitsProcessed
How To Configure#
Relevant Artifacts#
The table below describes the properties for this entity type:
| Name | Type | Is Mandatory | Data Type | Description |
|---|---|---|---|---|
| IoTMetadataDefinition | SmartTable | Yes | - | Metadata configuration for equipment integration |
| CustomIoTIPCCFXUnitsProcessedContext | SmartTable | Yes | - | Table used to Resolve data collection Parameter context |
| IoTIPCCFXUnitsProcessed | DEE | Yes | - | IPC CFX UnitsProcessed DEE |
IoTMetadataDefinition Resource Level Configuration#
At the Resource level, there are several configuration we can make to set this feature.
| Resource | Resource Type | Area | Name | Value | Description |
|---|---|---|---|---|---|
| MES IPC-CFX Resource | useIPCCFXtoUnitsProcessed | true or false | Toggle this feature on or off. | ||
| MES IPC-CFX Resource | useIPCCFXToTrackOut | UnitsProcessed | Enable Track-Out operation with the event defined. |
How It Works#
CFX.Production.UnitsProcessed Event from IPC-CFX standard.
Process Data#
- It resolves the SmartTable
IoTMetadataDefinitionto check if the configurationuseIPCCFXtoUnitsProcessedis defined, if so, it will execute the UnitsProcessed Workflow. - It also will resolve the SmartTable
CustomIoTIPCCFXUnitsProcessedContextto associate the UnitsProcessed data with the correct Parameters in the DataCollection.
In the Event message we will retrieve TransactionId and CommonProcessData and UnitProcessData objects.
Currently supported Processes
- Conformal Coating Process
- Reflow Profiling Device
- Selective Soldering
CFX UnitsProcessed Example
{
"TransactionId": "d280fd1c-e2cb-4544-be8b-78554c87a0c5",
"OverallResult": "Succeeded",
"CommonProcessData": null,
"UnitProcessData": [
{
"UnitIdentifier": "CARRIER55678",
"UnitPositionNumber": 1,
"UnitResult": "Succeeded",
"UnitProcessData": {
"$type": "CFX.Structures.Coating.CoatingProcessData, CFX",
"Readings": [
{
"MeasurementType": "FluidVolume",
"ActualValue": 1.1,
"ExpectedValue": 1.0,
"MinAcceptableValue": 0.8,
"MaxAcceptableValue": 1.2,
"UniqueIdentifier": "c3113de4-c3f9-4c9d-8814-fee2ea12e90b",
"MeasurementName": "FluidVolume",
"TimeRecorded": null,
"Sequence": 0,
"Result": "Passed",
"CRDs": null
},
{
"MeasurementType": "FluidPressure",
"ActualValue": 32.5,
"ExpectedValue": 32.0,
"MinAcceptableValue": 31.0,
"MaxAcceptableValue": 33.8,
"UniqueIdentifier": "fd246214-573b-40dd-927a-ebfb49d46ae7",
"MeasurementName": "FluidPressure",
"TimeRecorded": null,
"Sequence": 0,
"Result": "Passed",
"CRDs": null
}
]
}
},
{
"UnitIdentifier": "CARRIER55678",
"UnitPositionNumber": 2,
"UnitResult": "Succeeded",
"UnitProcessData": {
"$type": "CFX.Structures.Coating.CoatingProcessData, CFX",
"Readings": [
{
"MeasurementType": "FluidVolume",
"ActualValue": 1.1,
"ExpectedValue": 1.0,
"MinAcceptableValue": 0.8,
"MaxAcceptableValue": 1.2,
"UniqueIdentifier": "11508f6f-fa11-4533-9db0-d3ff99bb03ba",
"MeasurementName": "FluidVolume",
"TimeRecorded": null,
"Sequence": 0,
"Result": "Passed",
"CRDs": null
},
{
"MeasurementType": "FluidPressure",
"ActualValue": 32.5,
"ExpectedValue": 32.0,
"MinAcceptableValue": 31.0,
"MaxAcceptableValue": 33.8,
"UniqueIdentifier": "a0fff961-4fb4-4851-932d-fb811d2fe83d",
"MeasurementName": "FluidPressure",
"TimeRecorded": null,
"Sequence": 0,
"Result": "Passed",
"CRDs": null
}
]
}
}
]
}
Track-Out Operation#
- If the configuration