How to: Create a BOM for Weigh and Dispense#
A BOM with the Weigh and Dispense scope defines the formula that the operator follows: the raw materials to weigh, the quantity of each raw material, and the accepted tolerances.
Sequence of Steps#
1. Create the BOM#
- In the left side menu, select Business Data.
- From the Business Data panel, select BOM.
-
In the top ribbon, select New.
-
Select an available Change Set or create a new one, and then select Next.
Info
For more information, see Change Set Page.
-
In General Data, complete the following fields:
- Name: Enter the name of the BOM. For example,
BOM W&D Compound G. - Type: Select the type of the BOM. For example,
Standard. - Scope: Select
Weigh And Dispense. - Product: Select the target Product. For example,
Green Compound. - Units: Select the unit of the BOM. For example,
Kg. - Weigh and Dispense Label: Optionally, select a Printable Document with the Weigh and Dispense Label scope. The system prints the label automatically after each partial or complete dispense.
- Formula Type: Select one of the following options:
Absolute: The BOM expresses the quantities and the tolerances in absolute values. The sum of the BOM quantities can add up to any value.Relative: The BOM expresses the quantities as percentages. The sum of the BOM quantities must add up to a value between 99 and 101. The tolerances are percentages of the calculated quantity to dispense.
- Name: Enter the name of the BOM. For example,
-
Select Create.
Info
For more information, see Create BOM.
2. Add the BOM Items#
- In the BOM Items section of the new BOM, select Manage.
- Select to add an item for each raw material.
-
For each item, complete the following fields:
- Product: Select the raw material Product.
- Quantity: Enter the quantity of the raw material. For a Relative BOM, enter a percentage.
- Units: Select the unit of the raw material. For a Relative BOM, the system uses the BOM unit.
- Source Step: Select the Step where the raw material resides.
- Lower Tolerance and Upper Tolerance: Enter the accepted deviation from the quantity.
- Assembly Step: Select the Step where the operator weighs and dispenses the raw material.
- Instrument Type: Select the type of Instrument that must weigh the raw material.
- Quantity Calculation Rule: Optionally, select a Rule that calculates the quantities during the operation. For more information, see Calculate the Quantities to Weigh.
- Note: Optionally, enter instructions that the system shows to the operator during the operation.
-
Select Update.
The following images show a Relative BOM and an Absolute BOM with their items.
Warning
The system accepts only BOMs where all or none of the items have an Assembly Step.
Info
Add the items in the sequence that the operator dispenses them. The system uses this sequence to show the previous and the upcoming dispenses on the Weigh & Dispense page.
Units of Measure#
A BOM can include different units for different ingredients. For a BOM with the Weigh and Dispense scope, unit conversion factors must exist between the units of each ingredient Product and the primary units of the target Material. Define the factors in the Unit Conversion Factors section of the Product. For more information, see Manage Unit Conversion Factors.
Expected Result#
The BOM exists with the Weigh and Dispense scope and its items. After the BOM is Active or Effective, associate it with a Step and a Product in the BOMContext smart table. For more information, see Configure Weigh and Dispense.