Weigh and Dispense Across Multiple Steps#
In this scenario, you will learn how to:
- Apply a single BOM across multiple Steps.
- Dispense an ingredient in partial quantities.
- Consume the dispensed ingredients into the target Material.
Info
Complete Configure Weigh and Dispense first. This scenario uses BOM W&D Compound G with the Consume mode in the Chemicals Preparation and Chemicals Preparation and Mixing Steps. For more information, see:
Sequence of Steps#
1. Set the Configuration Entries#
- In the left side menu, select Administration.
- From the Administration panel, select Configuration.
- Set the entries in the following table. They are under
/Cmf/System/Configuration/WeighAndDispense/.
| Entry | Value |
|---|---|
PrecisionQuantum | 2 |
ForceVerification | false |
DefaultPartialDispenseButton | DispenseAndReset |
AccuracyQuantum | 1 |
HideContainerFields | false |
Table: Configuration entries of the scenario
The master data file provides the remaining configuration.
Warning
Set the Primary Quantity of Green Compound#01 to zero, and define the Target Material Quantity, before you start. In this scenario, the target quantity is 25 Kg. Each Weigh and Dispense operation adds the dispensed quantity to the Primary Quantity.
2. Track-In the Material#
- Open the
Chemicals PreparationStep. - In Materials, select
Green Compound#01. - Track-In the Material.
-
Select Weigh & Dispense on the top ribbon.
-
Review the safety information that the Product defines, and select Proceed to W&D.
3. Dispense the First Ingredient in Partial Quantities#
- Select the scale that matches the Instrument Type of the BOM item and that the Measurement Capabilities allow for the quantity to weigh.
- In Source, select the source Material. For example,
Powdered chemical Green#04. - Optionally, select the source Container.
- Optionally, select the target Container.
-
Optionally, select Show all steps to see the BOM items of the current and the later Steps.
If you assigned documents to the Product, they also appear in the wizard.
-
Select Set Tare & Begin to acknowledge the tare and start weighing.
-
Weigh a partial quantity of the ingredient, or insert the weight. For example, select Insert Weight, enter
1.5, and select OK. The Required Quantity is2.2727 Kg (2.2273 - 2.2955).Because the weight is lower than the required quantity, the Dispense & Reset and Dispense & Continue options are available.
Option Behavior Dispense & Reset Resets the dispensed quantity to zero and adjusts the target quantity accordingly. This is the default, because DefaultPartialDispenseButtonisDispenseAndReset.Dispense & Continue Keeps the dispensed quantity, and the target quantity stays the same. -
Select Dispense & Reset.
- Select Set Tare & Begin again to start weighing the remaining quantity.
- Weigh the remaining quantity of the ingredient, or insert it, and select Dispense.
4. Dispense the Second Ingredient#
- Select the next ingredient,
Phthalates. - Select the scale and the source Material. For example,
Phthalates#04. - Select Set Tare & Begin to acknowledge the tare and start weighing.
- Weigh the ingredient, or insert the weight
13.64. The Required Quantity is13.6364 Kg (12.7273 - 14.3182). -
Select Dispense.
5. Complete the First Step#
- Select Complete W&D.
-
Open
Green Compound#01and verify the Primary Quantity. It increases by the dispensed quantities of the ingredients, to15.9127 Kg.
The Material has no Sub-Materials, because the BOM Context defines the Consume mode.
6. Dispense the Remaining Ingredient in the Next Step#
- Track-Out
Green Compound#01and move it to the next assembly Step,Chemicals Preparation and Mixing. - Track-In the Material, and select Weigh & Dispense.
- Select the
Secret Chemical Recipeingredient, the scale, and the source Material. - Select Set Tare & Begin to acknowledge the tare and start weighing.
- Weigh the ingredient, or insert the weight
9.09. The Required Quantity is9.0909 Kg (9.0455 - 9.1136). - Select Dispense.
-
Select Complete W&D.
7. Verify the Result#
-
Open
Green Compound#01and verify the Primary Quantity. It is now25.0027 Kg. -
Check the information on the following pages:
- Material History
- Traceability view
- Genealogy
Note
After all the partial Weigh and Dispense operations are complete, remove the Target Material Quantity and the Target Material Units of the Material. Otherwise, the system restricts several operations for the Material.
Expected Result#
After the operations in all the Steps, the Primary Quantity of Green Compound#01 matches the target quantity or is within the tolerances that the BOM defines. In this scenario, 25.0027 Kg is within the tolerances for a target quantity of 25 Kg.
Next Scenario#
Continue with Electronic Scale Integration.