Skip to content

Weigh and Dispense Across Multiple Steps#

In this scenario, you will learn how to:

  • Apply a single BOM across multiple Steps.
  • Dispense an ingredient in partial quantities.
  • Consume the dispensed ingredients into the target Material.

Info

Complete Configure Weigh and Dispense first. This scenario uses BOM W&D Compound G with the Consume mode in the Chemicals Preparation and Chemicals Preparation and Mixing Steps. For more information, see:

Sequence of Steps#

1. Set the Configuration Entries#

  1. In the left side menu, select Administration.
  2. From the Administration panel, select Configuration.
  3. Set the entries in the following table. They are under /Cmf/System/Configuration/WeighAndDispense/.
Entry Value
PrecisionQuantum 2
ForceVerification false
DefaultPartialDispenseButton DispenseAndReset
AccuracyQuantum 1
HideContainerFields false

Table: Configuration entries of the scenario

The master data file provides the remaining configuration.

Warning

Set the Primary Quantity of Green Compound#01 to zero, and define the Target Material Quantity, before you start. In this scenario, the target quantity is 25 Kg. Each Weigh and Dispense operation adds the dispensed quantity to the Primary Quantity.

2. Track-In the Material#

  1. Open the Chemicals Preparation Step.
  2. In Materials, select Green Compound#01.
  3. Track-In the Material.
  4. Select Weigh & Dispense on the top ribbon.

    Step page that lists Green Compound#01 and shows the Weigh and Dispense button on the top ribbon.

  5. Review the safety information that the Product defines, and select Proceed to W&D.

3. Dispense the First Ingredient in Partial Quantities#

  1. Select the scale that matches the Instrument Type of the BOM item and that the Measurement Capabilities allow for the quantity to weigh.
  2. In Source, select the source Material. For example, Powdered chemical Green#04.
  3. Optionally, select the source Container.
  4. Optionally, select the target Container.
  5. Optionally, select Show all steps to see the BOM items of the current and the later Steps.

    If you assigned documents to the Product, they also appear in the wizard.

    Weigh and Dispense page with the Show all steps option, the source, the target, and the scale.

  6. Select Set Tare & Begin to acknowledge the tare and start weighing.

  7. Weigh a partial quantity of the ingredient, or insert the weight. For example, select Insert Weight, enter 1.5, and select OK. The Required Quantity is 2.2727 Kg (2.2273 - 2.2955).

    Insert Weight Manually dialog with the value 1.5 Kg.

    Because the weight is lower than the required quantity, the Dispense & Reset and Dispense & Continue options are available.

    Weigh and Dispense page with a weight of 1.5 Kg, below the required quantity, and the partial dispense options.

    Option Behavior
    Dispense & Reset Resets the dispensed quantity to zero and adjusts the target quantity accordingly. This is the default, because DefaultPartialDispenseButton is DispenseAndReset.
    Dispense & Continue Keeps the dispensed quantity, and the target quantity stays the same.
  8. Select Dispense & Reset.

  9. Select Set Tare & Begin again to start weighing the remaining quantity.
  10. Weigh the remaining quantity of the ingredient, or insert it, and select Dispense.

4. Dispense the Second Ingredient#

  1. Select the next ingredient, Phthalates.
  2. Select the scale and the source Material. For example, Phthalates#04.
  3. Select Set Tare & Begin to acknowledge the tare and start weighing.
  4. Weigh the ingredient, or insert the weight 13.64. The Required Quantity is 13.6364 Kg (12.7273 - 14.3182).
  5. Select Dispense.

    Weigh and Dispense page with 13.64 Kg of Phthalates within the tolerance limits.

5. Complete the First Step#

  1. Select Complete W&D.
  2. Open Green Compound#01 and verify the Primary Quantity. It increases by the dispensed quantities of the ingredients, to 15.9127 Kg.

    Details of Green Compound#01 with a Primary Quantity of 15.9127 Kg and a Target Quantity of 25 Kg.

The Material has no Sub-Materials, because the BOM Context defines the Consume mode.

6. Dispense the Remaining Ingredient in the Next Step#

  1. Track-Out Green Compound#01 and move it to the next assembly Step, Chemicals Preparation and Mixing.
  2. Track-In the Material, and select Weigh & Dispense.
  3. Select the Secret Chemical Recipe ingredient, the scale, and the source Material.
  4. Select Set Tare & Begin to acknowledge the tare and start weighing.
  5. Weigh the ingredient, or insert the weight 9.09. The Required Quantity is 9.0909 Kg (9.0455 - 9.1136).
  6. Select Dispense.
  7. Select Complete W&D.

    Weigh and Dispense page of the second Step with 9.09 Kg of Secret Chemical Recipe and the Complete W&D option.

7. Verify the Result#

  1. Open Green Compound#01 and verify the Primary Quantity. It is now 25.0027 Kg.

    Details of Green Compound#01 with a Primary Quantity of 25.0027 Kg and a Target Quantity of 25 Kg.

  2. Check the information on the following pages:

Note

After all the partial Weigh and Dispense operations are complete, remove the Target Material Quantity and the Target Material Units of the Material. Otherwise, the system restricts several operations for the Material.

Expected Result#

After the operations in all the Steps, the Primary Quantity of Green Compound#01 matches the target quantity or is within the tolerances that the BOM defines. In this scenario, 25.0027 Kg is within the tolerances for a target quantity of 25 Kg.

Next Scenario#

Continue with Electronic Scale Integration.