Weigh and Dispense in a Single Step#
In this scenario, you will learn how to:
- Weigh and dispense all the ingredients of a BOM in a single Step.
- Require a second person to verify each dispense.
- Attach the dispensed ingredients to the target Material as Sub-Materials.
Info
Complete Configure Weigh and Dispense first. This scenario uses BOM W&D Compound B with the Attach mode. For more information, see:
Sequence of Steps#
1. Set the Configuration Entries#
- In the left side menu, select Administration.
- From the Administration panel, select Configuration.
- Set the entries in the following table. They are under
/Cmf/System/Configuration/WeighAndDispense/.
| Entry | Value |
|---|---|
PrecisionQuantum | 2 |
ForceVerification | true |
DefaultPartialDispenseButton | DispenseAndContinue |
AccuracyQuantum | 1 |
HideContainerFields | true |
Table: Configuration entries of the scenario
The master data file provides the remaining configuration.
2. Track-In the Material#
- Open the
Chemicals PreparationStep. - In Materials, select
Blue Compound#01. - Track-In the Material.
3. Open Weigh and Dispense#
-
Select
Blue Compound#01, and then select Weigh & Dispense on the top ribbon. -
If the wizard shows the Printer field, select the printer. For example,
General. Select Next. - Review the safety information that the Product defines.
-
Select Proceed to W&D.
4. Dispense the First Ingredient#
- Select the scale. The
Powdered chemical Blueitem requires a scale of the Instrument TypeScale High Precision. For example, selectMDLSCL#10. -
In Source, select the source Material. For example,
Powdered chemical Blue#04.The page shows the Required Quantity of the ingredient,
5.0000 Kg (4.9950 - 5.0005), and the Note of the BOM item. -
Select Set Tare & Begin to acknowledge the tare and start weighing.
-
Weigh the ingredient on the scale.
To enter the weight manually, select Insert Weight on the top ribbon, enter
4.996, and select OK. This option requires theMaterial.WeighAndDispenseManualfeature. -
Select Dispense.
-
In the Sign dialog, the system requires two signatures, because Force Signature is enabled for
Material.WeighAndDispenseandForceVerificationistrue. Complete Performed By and Verified By with the credentials of two different users, and select Save.
The system attaches the dispensed quantity to Blue Compound#01 as a Sub-Material, because the BOM Context defines the Attach mode.
5. Dispense the Second Ingredient#
- Select the next ingredient,
Phthalates. - Select the scale. The
Phthalatesitem requires a scale of the Instrument TypeStandard Scale. - Select the source Material. For example,
Phthalates#04. - Select Set Tare & Begin to acknowledge the tare and start weighing.
-
Weigh the ingredient, or insert the weight
19.61. The Required Quantity is20.0000 Kg (19.6000 - 20.2000).The page confirms that the weight is valid and that you can dispense the quantity.
-
Select Dispense, and sign as in the previous ingredient.
6. Complete Weigh and Dispense#
7. Track-Out and Check the Traceability#
- Track-Out
Blue Compound#01. - Check the information on the following pages:
- Material History
- Traceability view
- Genealogy
Expected Result#
The two ingredients appear as Sub-Materials of Blue Compound#01, each with the dispensed quantity. In Attach mode, the quantity of the target Material stays at zero, because the Sub-Materials hold the whole quantity. The Material History, the Traceability view, and the Genealogy show the source Materials and the dispensed quantities.
Next Scenario#
Continue with Weigh and Dispense Across Multiple Steps.