跳转至

Equipment Configuration#

The Equipment Configuration task allows the user to configure the driver settings.

equipment_config

Inputs#

Name Data Type Description
Activate any Activates the task

Outputs#

Name Data Type Description
Success Boolean If there was no problem emits a true
Error Error Error that occurred during the processing of this task

Settings#

Name Data Type Default Description
Connecting Timeout Integer 30000 Number of milliseconds to wait while trying to establish a communication with the equipment interface
Setup Timeout Integer 10000 Number of milliseconds to wait while setup is being performed.
Setup phase is between onSetup and success stages of On Equipment Setup and Equipment Setup Result
Reconnect Interval Integer 5000 Number of milliseconds to wait between failed connection attempts
Heartbeat Interval Integer 60000 Number of milliseconds to separate the onHeartbeat outputs to be triggered. Use this option to validate if the connection with the equipment is still valid. Some protocols may not detect connection drops in realtime.

Each protocol driver as its own communication settings. They will be listed in the Inputs tab in a list. These values will be the ones sent to the driver if no link is used to override them.

Behavior#

The Equipment Configuration is typically when configuring the driver, before connecting the driver. In order to do a start sequence for the driver, this task can be used with the Driver Event task, with OnIntialize and AutoSetup and after completing using the task Driver Command to send a connect command to the driver.

Remarks#

There is no particular remark to be made.