Skip to content

Send Fuji Nexim Reply#

This Task is specific to be used with the Fuji Nexim Driver.

This Task sends reply messages of a specific type, which can be configured in the Task's settings.

sendfujineximreply_parameters

Inputs#

Name Data Type Description
requestId string The RequestId of the message received
Activate Boolean Activates the task

Outputs#

Name Data Type Description
Success Boolean If there was no problem emits a true
Error Error Error that occurred during the processing of this task

Settings#

On the General Tab, you have the usual settings and the following settings:

Name Data Type Values Default Description
Clear Inputs (on activate) Boolean true Defines if it is to clear the input values after receiving an activate
Message Full Name string Name of the message from Fuji Nexim specification, e.g.: STARTEV_ACK.
Message enum BOM List Reply
Machine State Change Reply
Panel CheckIn Reply
Panel CheckOut Reply
Program Change Completion Reply
Program Change Completion 2 Reply
Production Completed Reply
Production Start Reply
Specifies the behavior of the task

sendfujineximreply_settings

Behavior#

When activated, this Task sends a reply of a specific message, configured in the settings.

The requestId input is important to identify the request to be replied to.

Remarks#

None.