Send Fuji Nexim Reply#
This Task is specific to be used with the Fuji Nexim Driver.
This Task sends reply messages of a specific type, which can be configured in the Task's settings.
Inputs#
| Name | Data Type | Description |
|---|---|---|
| requestId | string | The RequestId of the message received |
| Activate | Boolean | Activates the task |
Outputs#
| Name | Data Type | Description |
|---|---|---|
| Success | Boolean | If there was no problem emits a true |
| Error | Error | Error that occurred during the processing of this task |
Settings#
On the General Tab, you have the usual settings and the following settings:
| Name | Data Type | Values | Default | Description |
|---|---|---|---|---|
| Clear Inputs (on activate) | Boolean | true | Defines if it is to clear the input values after receiving an activate | |
| Message Full Name | string | Name of the message from Fuji Nexim specification, e.g.: STARTEV_ACK. | ||
| Message | enum | BOM List ReplyMachine State Change ReplyPanel CheckIn ReplyPanel CheckOut ReplyProgram Change Completion ReplyProgram Change Completion 2 ReplyProduction Completed ReplyProduction Start Reply | Specifies the behavior of the task |
Behavior#
When activated, this Task sends a reply of a specific message, configured in the settings.
The requestId input is important to identify the request to be replied to.
Remarks#
None.