Setup Center Material Reordered#
The Setup Center Material Moved task informs whenever a reorder was initiated on the line.
Inputs#
| Name | Data Type | Description |
|---|---|---|
| Activate | Any | Activate the task |
Outputs#
| Name | Data Type | Description |
|---|---|---|
| factoryLocation | String | Name of the location inside the factory |
| line | String | Line name, where the reorder takes place Range: 1- 256 signs. |
| component | String | Component name within SIPLACE Pro. Range: 1- 256 signs |
| division | String | Division of the feeder, where the component is setup up (component based). Range: 1-3 |
| timestamp | DateTime | MSD open date |
| level | String | Level within a carrier, where the component is set up (component based). This property is required for MTC/WPW/TrayStack, else 0 |
| tower | String | Tower number of a MTC / WPW, else 0(component based). |
| stationTrack | String | This is the number of the track on the station based on the track ruler for this component location. |
| machineId | String | Machine id which is unique for all machines worldwide |
| location | Integer | Station location (feeder based). Range: 1-4 |
| cassetteLevel | Integer | This is the level within the cassette(not to be confused with the level in the tray feeder). |
| dockingStationId | String | Docking station identifier. |
| tableId | String | Changeover table identification. |
| feederId | String | Feeder identification. |
| feederType | Integer | Feeder type (is equivalent to MC number). |
| cartridgeId | String | Cartridge identifier. The cartridge id is only available for the Bulkfeeder X. |
| cassetteId | String | Cassette identifier. |
| Success | Boolean | Triggered when the task is executed with success |
| Error | Error | Triggered when the task failed for some reason |
Settings#
On the General tab, you have the usual settings and the following settings:
| Name | Data Type | Values | Default | Description |
|---|---|---|---|---|
| Auto Activate | Boolean | true | On initializing the task, subscribes it to the Gate Keeper Messages. If false, only subscribes on Activate. |
Behavior#
This task captures the SetupCenter interface, whenever a reorder was initiated on the line.
Remarks#
None.