Unload Feeder from Position#
Overview#
Unload the Consumable Feeders from Station Position.
Relevant Artifacts#
The table below describes the properties for this entity type:
| Name | Type | Is Mandatory | Data Type | Description |
|---|---|---|---|---|
| IoTMetadataDefinition | SmartTable | Yes | Metadata configuration for equipment integration | |
| IoTFujiNeximUnloadComponents | DEE | Yes | Detach feeders from a specified MES resource |
How It Works#
When a UNLOADCOMP event is received from a Fuji NXT III machine, the following process is executed:
Area Feature Checks#
- Resolves the MES Resource Name using
FUJI_LineNameMachineNameModuleNo_.
Resource Feature Checks#
- It checks whether the
UseFujiToUnloadCompfeature is enabled for the MES Resource inST_IoTMetadataDefinition.
MES Operations#
- If the feature is enabled, the Automation Controller calls the DEE IoTFujiNeximUnloadComponents, passing:
- The MES Resource Name
- A list of components to be unloaded
- The DEE performs the following actions:
- Detaches the Consumable Feed
- Updates the quantity of the Consumables
Sends a UNLOADCOMP_ACK message back to the equipment, which includes:
- A list of components
- A result (
0 (Ok)or1 (NOk)) for each component
Error Handling
If any component fails during the DEE operation, the entire set operation is considered failed.
Bypass Condition
If UseFujiToLoadComp is set to False or not defined, the DEE call is bypassed entirely.
Assumptions#
SmartTable IoTMetadataDefinition is configured with the following entry for each station:
| Resource | ResourceType | Area | Name | Value |
|---|---|---|---|---|
| MES Fuji Station X Resource | UseFujiToUnloadComp | True |