Skip to content

Automatic Resource State Change#

The features handled in this integration have as base PanaCIM v8831 specification.

Overview#

This feature enables the automatic change of MES Resource state according to PanaCIM state.

How To Configure#

Allow the user to adjust MES Resource state in relation with PanaCIM machine state automatically.

Relevant Artifacts#

The table below describes the properties for this entity type:

Name Type Is Mandatory Data Type Description
IoTMetadataDefinition SmartTable Yes Metadata configuration for equipment integration
IoTStateModelContext SmartTable Yes Relates the state model of the equipment to the state model of MES resource

How It Works#

We receive from PanaCIM event 540 Machine Status Notification from this we will retrieve the Machine Status ID which we will relate to a MES state by resolving IoTStateModelContext.

Assumptions#

SmartTable IoTMetadataDefinition is configured, other than the generic keys (check Setup for more information), with the following entries for each station:

Resource ResourceType Area Name Value Description
MES PanaCIM Station X Resource usePanaCIMToChangeState 540MachineStatusNotification Activate change state through Event data.
MES PanaCIM Station X Resource useStateChangingWait true/false Wait for previous state change call to finish. If not set will default to false. Max 3 seconds.
MES PanaCIM Station X Resource useUpdateResourceLaneState true/false Update Resource Lanes State. If not set will default to false.

SmartTable IoTStateModelContext is configured with the entries for each state. The Driver PanaCIM name is mandatory. StateModelState and Values are according to MES Definition and Equipment State Number:

StateModel Driver StateModelState Values
SEMI E10 PanaCIM MES State PanaCIM State

PanaCIM Machine Module Status Codes#

Below is a list of status codes used by PanaCIM machine modules, along with their meanings:

Code Status Description
0 Running Actively mounting parts
1 Waiting Waiting for a command other than START
2 Exhaust
3 Error
4 Reserved
5 Product Change Over Module is in changeover status