# IoT Runtime Components Configuration
The configuration file is a JSON structured file and it will be used by all components (Manager, Monitor, Controller, Driver). It allows the use of some tokens to be inserted depending on the context, those tokens are explained in the following table:
| Name | Type | Usage | Description |
| --------------- | ----------------- | ---------------------- | ------------------------------------------------------------------------------------------------------------------ |
| applicationName | `Application` | ``${applicationName}`` | The name of the current application |
| pid | `Application` | ``${pid}`` | The process id of the current application |
| componentId | `Application` | `${componentId}` | Name of the component running (`AutomationManager`, `AutomationMonitor`, `AutomationController`, `DriverCsv`, etc) |
| entityName | `Application` | ``${entityName}`` | The name of the context entity for the current application |
| tmp | `OperatingSystem` | `${tmp}` | User temporary directory |
| pwd | `OperatingSystem` | `${pwd}` | Running script location |
| cwd | `OperatingSystem` | `${cwd}` | Working directory (where the command is being executed) |
Table: Connect IoT Configuration Tokens
## Where the Configuration Lives
MES holds the configuration of each **Automation Manager**: the one you set with [[user-guide-automation-manager-configure]] or, while the manager has none, the configuration entry `/Cmf/System/Configuration/ConnectIoT/ConfigurationTemplate`. The file on the manager host holds what the processes need to reach MES.
- The package that **Download** creates has a `config.json` with the `id`, `isMinimal` set to `true`, and the `system` section, which holds the access token (see [[operation-guide-connectiotadministration#access-tokens]]). It also has `config.full.json`, a copy of the full configuration at the time of the download.
- When `isMinimal` is `true`, the monitor reads the full configuration from MES each time it starts, keeps the local `system` section, and writes the result to `config.downloaded.json` next to `config.json`. Until then, the manager and the monitor log only to the console.
- When the **Automation Manager** is saved in MES, the running monitor writes `config.downloaded.json` again. Controller and driver processes read that file when they start, so an instance takes the change at its next restart. The monitor takes it when it starts again, and the manager then reloads its logging settings.
- When `isMinimal` is `false` or missing, the processes use the local file as it is, and changes in MES do not reach them.
## Base Structure
| Name | Type | Default Value | Description |
| ------------------ | ------------ | ---------------------- | --------------------------------------------------------------- |
| id | String | | Identifier of the process |
| monitorHost | String | ``"localhost"`` | Address of the local monitor listener address |
| monitorPort | Integer | ``0`` | Port of local monitor listener. 0 for automatic port assignment |
| cache | String | | Local path where the packages will be downloaded and executed |
| monitorApplication | String | `""${pwd}\monitor.js"` | Complete path of the Monitor process |
| repository | `Repository` | | Repository regarding packages handling |
| system | `System` | | System access settings |
| storage | `Storage` | | Section to configure persistency location |
| logging | `Logging` | | Logging mechanism settings |
| monitor | `monitor` | | Monitor process specific settings |
| controller | `controller` | | Controller(s) process(es) specific settings |
| driver | `driver` | | Driver(s) process(es) specific settings |
Table: Connect IoT Base Structure
## Repository Structure
The repository represents the way the Monitor process handles the location where the packages are located (remote) and stored (local).
| Name | Type | Possible Values | Default Value | Description |
| -------- | ------ | -------------------------------------- | ------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| type | String | ``Npm``
``Directory``
``System`` | | Type of repository
- `Npm` - uses an NPM server
- `Directory` - uses a local directory with the packages and a json-based database descriptor
- `System` - downloads the packages from MES (retrieves settings from the `system` structure detailed below) |
| settings | Object | | | Repository settings (depending on the type) |
Table: Connect IoT Repository Structure
### Type `Npm` Settings
| Name | Type | Default Value | Description |
| ----- | ------ | ------------- | ---------------------------------------------------- |
| url | String | | URL where the NPM server is located (including port) |
| token | String | | Optional Bearer token used for authentication |
Table: Npm specific settings
### Type `Directory` Settings
| Name | Type | Default Value | Description |
| ---- | ------ | ------------- | ----------------------------------------------------------------------------------------------------------------- |
| path | String | | Directory where the packages are located. Must be accessible by process and currently, UNCs are **not** supported |
Table: Directory specific settings
### Directory Examples
```json
"repository": {
"type": "Npm",
"settings": {
"url": "YourNpmAddress",
"token": "YourNpmToken"
}
}
```
```json
"repository": {
"type": "Directory",
"settings": {
"path": "[UserSelectedDirectory]\\MyDirectoryRepository"
}
}
```
## Storage Structure
| Name | Type | Possible Values | Default Value | Description |
| ---------------------- | ----------------------- | --------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| type | String | ``Directory`` | ``Directory`` | Type of persistency location |
| settings | Object | | | Storage type settings |
| settings\path | String | | | Base path where the persistency data will be stored.
`OperatingSystem` tokens are supported |
| settings\retentionTime | `Integer`
`string` | | `"30d"` | Number of seconds to store the data. `0` means forever.
Supports string with a trailing token indicating the time unit:
`s` - seconds
`m` - minutes
`h` - hours
`d` - days
`w` - weeks (7 days)|
| settings\logMaxLength | `Integer` | | `4096` | Maximum number of characters displayed in the console when storing a value in storage. If the value exceeds this limit, it will be truncated for readability. |
Table: Connect IoT Storage Structure
### Storage Structure Examples
```json
"storage": {
"type": "Directory",
"settings": {
"path": "[UserSelectedDirectory]/Persistency",
"retentionTime": 3600,
"logMaxLength": 4096
}
}
```
```json
"storage": {
"type": "Directory",
"settings": {
"path": "[UserSelectedDirectory]/Persistency",
"retentionTime": "10d",
"logMaxLength": 0
}
}
```
## System Structure
| Name | Type | Default Value | Description |
| ---------------------- | ---------------- | --------------- | ---------------------------------------------------- |
| tenantName | String | | System Tenant name to use by the components |
| address | String | ``"localhost"`` | |
| port | Integer | | |
| timeout | Integer | | |
| useSsl | Boolean | `false` | |
| authentication | `Authentication` | | Object |
Table: Connect IoT System Structure
### `Authentication` Structure
| Name | Type | Possible Values | Default Value | Description |
| -------- | ------ | --------------------------------------- | ------------- | ----------------------------------------------- |
| type | String | `SecurityPortal`
`ClientCredentials` | | Authentication type to use |
| settings | Object | | | Authentication settings (depending on the type) |
Table: Authentication structure
### Authentication type `SecurityPortal` settings
| Name | Type | Default Value | Description |
| ------------------- | ------ | ------------- | ------------------------------------------------------------------------------------------------------------------------------------------- |
| clientId | String | | Id of the client accessing to (MES) |
| accessToken | String | | Security Portal generated long term Access Token. To be set on non-interactive scenarios with Security Portal |
| openIdConfiguration | String | | URL where the OpenId endpoint can be accessed. Example: `http://YourEnvironment/tenant/YourTenant/.well-known/openid-configuration` |
| applicationBaseUrl | String | | Optional: In the case of apps, the Monitor will send requests to this address |
Table: Authentication type SecurityPortal structure
### Authentication type `ClientCredentials` settings
| Name | Type | Default Value | Description |
| ------------------- | ------ | ------------- | ------------------------------------------------------------------------------------------------------------------------------------------- |
| clientId | String | | Id of the client accessing to (MES) |
| openIdConfiguration | String | | URL where the OpenId endpoint can be accessed. Example: `http://YourEnvironment/tenant/YourTenant/.well-known/openid-configuration` |
| applicationBaseUrl | String | | Optional: In the case of apps, the Monitor will send requests to this address |
| password | String | | Optional: Password to login - Should not be used |
Table: Authentication type SecurityPortal structure
### Examples
```json
"system": {
"tenantName": "YourTenant",
"address": "YourEnvironment",
"port": 8093,
"timeout": 60000,
"useSsl": false,
"authentication": {
"type": "SecurityPortal",
"settings": {
"clientId": "MES",
"accessToken": "user created access token",
"openIdConfiguration": "http://YourEnvironment/tenant/YourTenant/.well-known/openid-configuration"
}
}
}
```
```json
"system": {
"tenantName": "YourTenant",
"address": "YourEnvironment",
"port": 8093,
"timeout": 60000,
"useSsl": false,
"authentication": {
"type": "ClientCredentials",
"settings": {
"clientId": "MES",
"openIdConfiguration": "http://YourEnvironment/tenant/YourTenant/.well-known/openid-configuration"
}
}
}
```
## Logging Structure
The logging configuration allows several different loggers to be configured at same time, meaning that for each type of logger, different options can be configured.
| Name | Type | Possible Values | Default Value | Description |
| ------------ | --------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------- | -------------------------------------------------------------------------------------------- |
| id | String | | | Identifier of the logger, if none is configured, only one of the same type is allowed |
| type | String | ``Console``
``File``
``Http``
``OTLP`` | | Type of the transport |
| options | Object | | | Transport options,different for each type of transport, see each transport information below |
| applications | Array of String | ``AutomationMonitor``
``AutomationController``
``AutomationManager``
``DriverSecsGem``
``DriverOpcUA``
``DriverMqtt``
``DriverBle``
``DriverCsvFile``
``DriverRawFile``
``DriverKeyboardWedge``
``DriverOib``
``DriverOpcDA``
``DriverSerial``
`DriverTcpIp` | | A wildcard can configure all or filter by name, example: ’``Driver*``’ |
Table: Connect IoT Logging Structure
### Common Transport Options
These options apply to all types:
| Name | Type | Possible Values | Default Value | Description |
| ----------------- | ------- | ----------------------------------------------------- | ------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| level | String | ``debug``
``info``
``warn``
``error``
| ``"info"`` | Minimum level of messages that this transport should log. If `info`level is defined, all entries of level `info`, `warn` and `error` will be logged and `debug` entries will be ignored. |
| label | String | | ``"${applicationName}"`` | Label to append in the beginning of the log entry (if used in the format) |
| format | String | | ``"${log.timestamp}${log.level}:${log.message}"`` | Format of the line of the log |
| timestamp | Boolean | | ``true`` | Flag indicating if we should prepend output with timestamps. If function is specified, its return value will be used instead of timestamps |
| timestampFormat | String | | ``"YYYY-MM-DD HH:mm:ss.SSS"`` | Format of the timestamp in the log entry. Please refer to for full format information |
| maxLength | Integer | | ``0`` | Max length of the message entry to log (<=0 to ignore). If entry is larger than the value, will log (70% of the maxLength) of the start of the message and the last (30% of maxLength) characters. This setting is useful to keep huge communication logs in a more controllable state. |
| specificLevelLock | Boolean | | ``false`` | Only log the specified verbosity level. With this setting set to `true` the levels greater than the `level` will be ignored. |
| isEnabled | Boolean | | `true` | Is the Transport enabled |
Table: Connect IoT Common Transport Options
### Console Transport Options
This transport log all the messages to the application console.
| Name | Type | Default Value | Description |
| --------------- | ------- | ------------- | ----------------------------------------------------------------------- |
| colorize | Boolean | ``true`` | Flag indicating if we should colorize output. |
| colorizeMessage | Boolean | `true` | Is the colorization to apply to the full message or only the verbosity. |
Table: Connect IoT Console Transport Options
### Example
```json
{
"type": "Console",
"options": {
"level": "debug",
"prettyPrint": true,
"colorizeMessage": true
},
"applications": [ "*" ]
}
```
### File Transport Options
As the name states, this transport log all the messages to the file system.
| Name | Type | Default Value | Description |
| ----------- | ------ | ------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| frequency | String | | A string representing the frequency of rotation. This is useful if you want to have timed rotations, as opposed to rotations that happen at specific moments in time. Valid values are ``'#m'`` or ``'#h'`` (e.g., '5m' or '3h'). Leaving this null relies on datePattern for the rotation times. |
| datePattern | String | ``"YYYY-MM-DD"`` | A string representing the moment.js date format to be used for rotating. The meta characters used in this string will dictate the frequency of the file rotation. For example, if your datePattern is simply ``'HH'`` you will end up with 24 log files that are picked up and appended to every day. |
| filename | String | ``"LogFile_${date}.log"`` | Filename to be used to log to. This filename can include the ${date} placeholder which will include the formatted datePattern at that point in the filename |
| dirname | String | ``"."`` | The directory name to save log files to |
| maxSize | String | ``"10m"`` | Maximum size of the file after which it will rotate. This can be a number of bytes, or units of kb, mb, and gb. If using the units, add `k`, `m`, or `g` as the suffix. The units need to directly follow the number. |
| maxFiles | String | ``"30d"`` | Maximum number of logs to keep. If not set, no logs will be removed. This can be a number of files or number of days. If using days, add `d` as the suffix |
| option | Object | ``{ flags: 'a', mode: 0o777 }`` | An object resembling indicating additional options that should be passed to the file stream |
| auditFile | String | ``${dirname}/.audit.json`` | A string representing the name of the audit file. |
Table: Connect IoT File Transport Options
### File Transport Options Example
```json
{
"id": "MyFileLogger01",
"type": "File",
"options": {
"filename": "${applicationName}_${date}.log",
"dirname": "${tmp}/YourManager01/Logs/${applicationName}",
"level": "debug",
"timestampFormat": "HH:mm:ss.SSSSS",
"maxSize": "10m",
"maxFiles": 5,
"maxLength": 5000,
"specificLevelLock": false
},
"applications": [ "AutomationMonitor", "AutomationManager" ]
}
```
### HTTP Transport Options
The HTTP transport is a generic way to log, query, and stream logs from an arbitrary HTTP endpoint, preferably ``winstond``. It takes options that are passed to the node.js http or https request:
| Name | Type | Default Value | Description |
| ---- | ------- | ----------------- | -------------------------------------------------------------------- |
| host | String | ``"localhost"`` | Remote host of the HTTP logging endpoint. |
| port | Integer | ``80`` or ``443`` | Remote port of the HTTP logging endpoint. |
| path | String | ``"/"`` | Remote URI of the HTTP logging endpoint. |
| auth | Object | ``None`` | An object representing the username and password forHTTP Basic Auth. |
| ssl | Boolean | ``false`` | Value indicating if we should us HTTPS |
Table: Connect IoT HTTP Transport Options
### HTTP Transport Options Example
```json
{
"id": "MyHttp01",
"type": "Http",
"options": {
"host": "localhost",
"port": "80",
"path": "logger",
},
"applications": [ "AutomationController" ]
}
```
### OTLP Transport Options
The OTLP transport is a transport to broadcast logs using the open telemetry standard. When the endpoint is not configured, it is discovered from the MES (see [Default OTLP Endpoint](#default-otlp-endpoint)):
| Name | Type | Default Value | Description |
| ---------- | ------- | ------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| isEnabled | Boolean | | Flag to enable the transport. If not set, it is derived from the host's observability configuration (see note below). |
| level | String | | Logging Level. |
| isInternal | Boolean | False | Flag only used if the automation manager is running in the same stack as the MES application. |
| endpoint | String | | An external endpoint that receives and processes telemetry signals sent according to the OTLP (open telemetry protocol) format (i.e https://mytelemetrystack.com/telemetry/http). If not set, the telemetry address of the MES is used. |
| logsExportTimeoutMillis | Integer | | Maximum time (in milliseconds) allowed for a log batch export to complete before it is considered failed. Falls back to the `OTEL_BLRP_EXPORT_TIMEOUT` environment variable, then to the OpenTelemetry SDK default, when not set. |
Table: Connect IoT OTLP Transport Options
!!! info "isEnabled inherited from host observability settings"
When `isEnabled` is not explicitly set on the OTLP transport, the Automation Manager configuration derives it from the host's own observability configuration (the `OBSERVABILITY_ENABLED` environment variable and related settings). Set `isEnabled` explicitly to opt this transport in or out regardless of the host configuration.
### Default OTLP Endpoint
When an enabled OTLP transport has no `endpoint`, the Automation Monitor reads the telemetry address, `services.telemetry`, from the well-known configuration endpoint of the MES (`/.well-known/criticalmanufacturing-configuration`) when it authenticates. It then distributes the address to the Automation Manager, the Automation Controllers, and the drivers, including those that start or restart later.
- An `endpoint` set on the transport always takes priority over the discovered address.
- The discovered address must use `http` or `https`. If the well-known configuration endpoint cannot be reached, or does not return a valid telemetry address, the authentication with the MES fails.
- The default Automation Manager configuration no longer sets an endpoint. In earlier versions it set `http://traefik:8082/__internal/telemetry/http`, which is not valid for every deployment. Remove that value from custom configurations that copied it, unless it is the collector you intend to use.
### OTLP Transport Options Example
```json
{
"type": "OTLP",
"options": {
"isEnabled": true,
"level": "debug"
},
"applications": [ "*" ]
},
```
## Monitor Structure
The optional monitor section is specifically for the monitor process and are not used by the other applications.
| Name | Type | Default Value | Description |
| ----------------------- | ----------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| notifyBeforeKill | Boolean | `true` | Flag indicating if a notification to the processes before killing them (allowing them to properly cleanup any resources, disconnect from devices, etc), or simply kill them. |
| killNotificationTimeout | Integer | `10000` | Number of milliseconds to wait for the "about to be killed" process reply that it has finished the cleanup an is ready to be killed. |
| retryAttempts | Integer | `30` | When calls protected by retry mechanism fail, number of executions before failing |
| sleepBetweenAttempts | integer | `1000` | When calls protected by retry mechanism fail, time to wait between retries |
| processCommunication | `SslConfig` | | Configuration to allow inter-process communications to be using SSL (monitor <-> controller(s) and monitor <-> driver(s)) |
| otlp | `Object` | | Settings for the proactive refresh of the OTLP access token before it expires. See [OTLP Token Refresh Settings](#otlp-token-refresh-settings). |
| processHeartbeat | `Object` | | Settings for the heartbeat that detects a controller or driver process that stops answering. See [Process Heartbeat Settings](#process-heartbeat-settings). |
Table: Connect IoT Monitor Structure
### OTLP Token Refresh Settings
The Monitor owns the OTLP access token refresh lifecycle: it caches the latest token received from the Host, proactively refreshes it before expiry, retries on failure, and distributes the refreshed token to the Manager and to the running Controller/Driver processes so that OTLP telemetry keeps flowing without needing Host activity to trigger a refresh.
| Name | Type | Default Value | Description |
| ----------------------- | ------- | -------------- | ----------------------------------------------------------------------------------------------------- |
| refreshBeforeExpirySeconds | Integer | `600` | How many seconds before the access token's expiry the Monitor should proactively request a refresh. |
| retryAttempts | Integer | `60` | Number of retries after a failed refresh attempt. Set to `-1` to retry indefinitely. |
| retryDelaySeconds | Integer | `60` | Number of seconds to wait between failed refresh retries. |
Table: Connect IoT Monitor OTLP Token Refresh Settings
### Process Heartbeat Settings
The monitor sends a heartbeat to each controller and driver process that it runs on its host, every `interval` milliseconds. A process that does not reply within `timeout` counts one failure, and a reply resets the count. When the consecutive failures exceed `allowedFailures`, the monitor performs `action`. With the defaults, the action runs on the fourth failed heartbeat in a row.
| Name | Type | Default Value | Description |
| --------------- | ------- | ------------- | --------------------------------------------------------------------------------------------------------------------- |
| isEnabled | Boolean | `true` | Flag indicating if the monitor sends the heartbeat. When `false`, no process is checked. |
| interval | Integer | `60000` | Number of milliseconds between heartbeats. A value below `timeout` + `5000` is raised to that value. |
| timeout | Integer | `10000` | Number of milliseconds a process has to reply to a heartbeat. |
| allowedFailures | Integer | `3` | Number of consecutive failed heartbeats tolerated before the action. A negative value counts as `0`. |
| action | String | `Restart` | `Restart` kills the process so that it starts again. `None` only logs the failures. Any other value counts as `None`. |
Table: Connect IoT Monitor Process Heartbeat Settings
The monitor log shows each failure as `Process '' () failed to reply the heartbeat (attempt # /)`, and the action as `Process '' () exceeded the maximum amount of allowed failures. Performing action ''`. With the log level at `debug`, the controller and driver logs show `Heartbeat received from Monitor` for each heartbeat.
### Monitor Structure Example
```json
"monitor": {
"notifyBeforeKill": "true",
"killNotificationTimeout": 30000,
"retryAttempts": 45,
"sleepBetweenAttempts": 1000,
"processCommunication": {
"useSsl": true,
"privateKey": "YourCertificatesRepository\\key.pem",
"certificate": "YourCertificatesRepository\\cert.pem",
"certificateAuthority": "YourCertificatesRepository\\ca-cert.pem"
},
"otlp": {
"refreshBeforeExpirySeconds": 600,
"retryAttempts": 60,
"retryDelaySeconds": 60
},
"processHeartbeat": {
"isEnabled": true,
"interval": 60000,
"timeout": 10000,
"allowedFailures": 3,
"action": "Restart"
}
}
```
## Controller Structure
The optional controller section is specifically for the controller(s) process(es) and are not used by the other applications.
| Name | Type | Default Value | Description |
| ------------------------ | ------- | ------------- | --------------------------------------------------------------------------------- |
| retryAttempts | Integer | `30` | When calls protected by retry mechanism fail, number of executions before failing |
| sleepBetweenAttempts | integer | `1000` | When calls protected by retry mechanism fail, time to wait between retries |
| profilerSessionsLocation | string | | Location where the profiler sessions will be stored |
| contextManager | string | `ZoneJs` | Context manager used to track asynchronous execution state across workflow tasks, so data belonging to the same zone stays correlated. Possible values are `ZoneJs`, which relies on Zone.js and offers the broadest compatibility, and `Node`, which relies on Node.js's native `AsyncLocalStorage` |
Table: Connect IoT Controller Structure
### Controller Structure Example
```json
"controller": {
"retryAttempts": 45,
"sleepBetweenAttempts": 1000,
"profilerSessionsLocation": "YourControllerRepository\\tempController",
"contextManager": "Node"
}
```
## Driver Structure
The optional driver section is specifically for the driver(s) process(es) and are not used by the other applications.
| Name | Type | Default Value | Description |
| -------------------- | ----------- | ------------- | ------------------------------------------------------------------------------------------ |
| retryAttempts | Integer | `30` | When calls protected by retry mechanism fail, number of executions before failing |
| sleepBetweenAttempts | integer | `1000` | When calls protected by retry mechanism fail, time to wait between retries |
| processCommunication | `SslConfig` | | Configuration to allow inter-process communications to be using SSL (driver<-> controller) |
Table: Connect IoT Driver Structure
### Driver Structure Example
```json
"driver": {
"retryAttempts": 45,
"sleepBetweenAttempts": 1000,
"processCommunication": {
"useSsl": true,
"privateKey": "YourCertificatesRepository\\key.pem",
"certificate": "YourCertificatesRepository\\cert.pem",
"certificateAuthority": "YourCertificatesRepository\\ca-cert.pem"
}
}
```
## SslConfig structure
When communication between processes require SSL use these settings.
| Name | Type | Default Value | Description |
| -------------------- | ------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| useSsl | Boolean | `false` | Use SSL communication on component communication |
| rejectUnauthorized | Boolean | `false` | If not false a server automatically reject clients with invalid certificates.
Allows bypass of error: "Connection with monitor error: unable to verify the first certificate" on a completely unsecured way when set to false!
also, if we want to ignore environment variable "NODE_TLS_REJECT_UNAUTHORIZED=" we may set rejectUnauthorized: true
On self-signed certificates, we can pass the correct CA (certificate authority) certificate with certificateAuthority option |
| privateKey | string | | PEM encoded SSL private key Value or file full path containing the key value |
| certificate | string | | PEM encoded SSL certificate Value or file full path containing the certificate value |
| certificateAuthority | string | | PEM encoded SSL custom certificate authority (CA) Value or file full path containing the certificate value |
Table: Connect IoT SslConfig Structure
### SslConfig Structure Example
```json
{
"useSsl": true,
"privateKey": "YourCertificatesRepository\\key.pem",
"certificate": "YourCertificatesRepository\\cert.pem",
"certificateAuthority": "YourCertificatesRepository\\ca-cert.pem"
}
```
## SystemCertificate structure
When communication between processes require SSL use these settings.
| Name | Type | Default Value | Description |
| -------------------- | ------- | ------------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| rejectUnauthorized | Boolean | `false` | If rejectUnauthorized is set to true, it will change the environment variable of the process 'NODE_TLS_REJECT_UNAUTHORIZED' to '1', if set to false or not set it default to '0'. |
| certificate | string | | It will generate a temporary file and add the path to the environment variable of the process 'NODE_EXTRA_CA_CERTS'. |
| certificateAuthority | string | | It will append to the certificate and generate a temporary file and add the path to the environment variable of the process 'NODE_EXTRA_CA_CERTS'. value |
Table: Connect IoT SystemCertificate Structure
### SystemCertificate Structure Example
```json
{
"id": "MyManager",
"cache": "[MyCacheLocation]/Cache",
"hostName": "localhost",
"monitorApplication": "${pwd}/monitor.js",
"repository": {
"type": "System"
},
"system": {
"tenantName": "MyTenant",
"address": "MyAddress",
"port": 80,
"timeout": 120000,
"useSsl": false,
"isLoadBalancingEnabled": false,
"authentication": {
"type": "SecurityPortal",
"settings": {
"clientId": "MES",
"accessToken": "user access token",
"openIdConfiguration": "http://MyAddress/SecurityPortal/tenant/MyTenant/.well-known/openid-configuration"
}
}
},
"isMinimal": false,
"storage": {
"type": "Directory",
"settings": {
"path": "[MyPersistencyDirectory]/Persistency",
"retentionTime": "30d"
}
},
"logging": [
{
"type": "Console",
"options": {
"level": "debug",
"prettyPrint": true,
"colorizeMessage": true,
"isEnabled": true
},
"applications": [
"*"
]
},
{
"type": "OTLP",
"options": {
"level": "info",
"isEnabled": false
},
"applications": [
"*"
]
},
{
"id": "Controllers",
"type": "File",
"options": {
"filename": "${applicationName}_${date}.log",
"dirname": "[MyLogsDirectory]/Instances/${entityNameNormalized}/${componentId}",
"level": "debug",
"timestampFormat": "HH:mm:ss.SSSSS",
"maxSize": "10m",
"maxFiles": "30d",
"isEnabled": true
},
"applications": [
"AutomationController"
]
},
{
"id": "Drivers",
"type": "File",
"options": {
"filename": "${applicationName}_${date}.log",
"dirname": "[MyLogsDirectory]/Instances/${entityNameNormalized}/${componentId}",
"level": "debug",
"timestampFormat": "HH:mm:ss.SSSSS",
"maxSize": "10m",
"maxFiles": "30d",
"isEnabled": true
},
"applications": [
"Driver*"
]
},
{
"id": "ManagerAndMonitor",
"type": "File",
"options": {
"filename": "${applicationName}_${date}.log",
"dirname": "[MyLogsDirectory]/Instances/Manager/${applicationName}",
"level": "info",
"timestampFormat": "HH:mm:ss.SSSSS",
"maxSize": "10m",
"maxFiles": "30d",
"isEnabled": true
},
"applications": [
"AutomationMonitor",
"AutomationManager"
]
},
{
"id": "Jobs",
"type": "File",
"options": {
"filename": "Job_${jobId}_${date}.log",
"dirname": "${temp}/ConnectIoT/Jobs",
"auditFile": "${temp}/ConnectIoT/Jobs/.audit.json",
"level": "info",
"timestampFormat": "HH:mm:ss.SSSSS",
"maxSize": "10m",
"maxFiles": "30d",
"isEnabled": true
},
"applications": [
"AutomationJob"
]
}
]
}
```