--- alias: tutorials-weigh-and-dispense-single-step tags: - "11.3" description: "Weigh and dispense two ingredients into a target material in a single Step and attach them as Sub-Materials" --- # Weigh and Dispense in a Single Step In this scenario, you will learn how to: - Weigh and dispense all the ingredients of a **BOM** in a single **Step**. - Require a second person to verify each dispense. - Attach the dispensed ingredients to the target **Material** as **Sub-Materials**. !!! info Complete [[tutorials-weigh-and-dispense-scenario-configure]] first. This scenario uses `BOM W&D Compound B` with the Attach mode. For more information, see: - [[user-guide-weigh-and-dispense-material]] - [[user-guide-track-in-material]] - [[user-guide-track-out-material]] ## Sequence of Steps ### 1. Set the Configuration Entries 1. In the left side menu, select **Administration**. 2. From the Administration panel, select **Configuration**. 3. Set the entries in the following table. They are under `/Cmf/System/Configuration/WeighAndDispense/`. | Entry | Value | | --- | --- | | `PrecisionQuantum` | `2` | | `ForceVerification` | `true` | | `DefaultPartialDispenseButton` | `DispenseAndContinue` | | `AccuracyQuantum` | `1` | | `HideContainerFields` | `true` | Table: Configuration entries of the scenario The [master data file](master_data/weight-dispense-masterdata.xlsx) provides the remaining configuration. ### 2. Track-In the Material 1. Open the `Chemicals Preparation` **Step**. 2. In **Materials**, select `Blue Compound#01`. 3. Track-In the **Material**. ### 3. Open Weigh and Dispense 1. Select `Blue Compound#01`, and then select **Weigh & Dispense** on the top ribbon. ![Step page that lists Blue Compound#01 and shows the Weigh and Dispense button on the top ribbon.](images/single_step_select_material.png) 2. If the wizard shows the **Printer** field, select the printer. For example, `General`. Select **Next**. 3. Review the safety information that the **Product** defines. 4. Select **Proceed to W&D**. ![Safety information step of the Weigh and Dispense wizard for Blue Compound#01.](images/single_step_safety_information.png) ### 4. Dispense the First Ingredient 1. Select the scale. The `Powdered chemical Blue` item requires a scale of the Instrument Type `Scale High Precision`. For example, select `MDLSCL#10`. 2. In **Source**, select the source **Material**. For example, `Powdered chemical Blue#04`. The page shows the **Required Quantity** of the ingredient, `5.0000 Kg (4.9950 - 5.0005)`, and the **Note** of the **BOM** item. ![Weigh and Dispense page with the Powdered chemical Blue ingredient, its required quantity, the source material, and the scale.](images/single_step_execution_wizard.png) 3. Select **Set Tare & Begin** to acknowledge the tare and start weighing. 4. Weigh the ingredient on the scale. To enter the weight manually, select **Insert Weight** on the top ribbon, enter `4.996`, and select **OK**. This option requires the `Material.WeighAndDispenseManual` feature. ![Insert Weight Manually dialog with the value 4.996 Kg.](images/single_step_insert_weight.png) 5. Select **Dispense**. 6. In the **Sign** dialog, the system requires two signatures, because **Force Signature** is enabled for `Material.WeighAndDispense` and `ForceVerification` is `true`. Complete **Performed By** and **Verified By** with the credentials of two different users, and select **Save**. ![Sign dialog with the Performed By and Verified By signatures.](images/single_step_sign.png) The system attaches the dispensed quantity to `Blue Compound#01` as a **Sub-Material**, because the **BOM Context** defines the Attach mode. ![Sub-Materials section of Blue Compound#01 with the first Sub-Material of 4.996 Kg.](images/single_step_first_submaterial.png) ### 5. Dispense the Second Ingredient 1. Select the next ingredient, `Phthalates`. 2. Select the scale. The `Phthalates` item requires a scale of the Instrument Type `Standard Scale`. 3. Select the source **Material**. For example, `Phthalates#04`. 4. Select **Set Tare & Begin** to acknowledge the tare and start weighing. 5. Weigh the ingredient, or insert the weight `19.61`. The **Required Quantity** is `20.0000 Kg (19.6000 - 20.2000)`. The page confirms that the weight is valid and that you can dispense the quantity. ![Weigh and Dispense page with 19.61 Kg of Phthalates within the tolerance limits.](images/single_step_second_ingredient.png) 6. Select **Dispense**, and sign as in the previous ingredient. ### 6. Complete Weigh and Dispense 1. Select **Complete W&D**. 2. Verify that `Blue Compound#01` has two **Sub-Materials**, one for each ingredient. ![Sub-Materials section of Blue Compound#01 with two Sub-Materials, 4.996 Kg and 19.61 Kg.](images/single_step_submaterials.png) ### 7. Track-Out and Check the Traceability 1. Track-Out `Blue Compound#01`. 2. Check the information on the following pages: - [[user-guide-material-history-index|Material History]] - Traceability view - [[user-guide-material-genealogy|Genealogy]] ## Expected Result The two ingredients appear as **Sub-Materials** of `Blue Compound#01`, each with the dispensed quantity. In Attach mode, the quantity of the target **Material** stays at zero, because the **Sub-Materials** hold the whole quantity. The Material History, the Traceability view, and the Genealogy show the source **Materials** and the dispensed quantities. ## Next Scenario Continue with [[tutorials-weigh-and-dispense-multi-step]].