alias: user-guide-automation-task-fujinexim-onfujineximrequest
tags:
- automation tasks
description: "This task processes Fuji Nexim request messages, updating outputs with event details and configurable settings"
---
# On Fuji Nexim Request
This Task is specific to be used with the Fuji Nexim Driver.
This Task receives request messages of a specific type, which can be configured in the Task's settings.
The Task's static and dynamic outputs are updated after each event received.
![onfujineximrequest_parameters][onfujineximrequest_parameters]
!!! warning "Deprecated"
Starting with version 12.0.0, this task is deprecated and will be removed in a future version. Use the [[user-guide-automation-task-core-equipmentevent]] task with the configured Fuji Nexim request message as the event instead. On upgrade to version 12.0.0, Data Flow workflows using this task are migrated automatically and links from the `requestId` output are renamed to the `occurrenceId` output.
## Inputs
| Name | Data Type | Description |
|-----------|-----------|---------------------------------------|
| Activate | `Boolean` | Activates the task |
## Outputs
| Name | Data Type | Description |
|--------------|------------|--------------------------------------------------------|
| requestId | `string` | The RequestId of the message received |
| timestamp | `DateTime` | The timestamp for when the event is triggered |
| eventRawData | `any` | The raw automation event object |
| Success | `Boolean` | If there was no problem emits a true |
| Error | `Error` | Error that occurred during the processing of this task |
## Settings
On the *General Tab*, you have the usual settings and the following settings:
| Name | Data Type | Values | Default | Description |
|-------------------|-----------|---------------------------------------|----------------|-----------------------------------------------------------------------------------------------------------------------|
| Auto Activate | `Boolean` | | true | If the event is activated by the register of an event of that type or if it is only activated by the `activate` input |
| Message Full Name | `string` | | | Name of the message from Fuji Nexim specification, for example, STARTEV. Mandatory. |
| Message | `enum` | `BOM List`
`Machine State Change`
`Panel CheckIn`
`Panel CheckOut`
`Program Change Completion`
`Program Change Completion 2`
`Production Completed`
`Production Start` | | Specifies the behavior of the task. Mandatory. |
![onfujineximrequest_settings][onfujineximrequest_settings]
## Behavior
When activated, this Task subscribes to a specific request message, configured in the settings.
Every time a message is received (via request) it emits the respective results to its outputs.
When you select a message, the task creates the dynamic outputs that correspond to the event properties of the selected message. The event type of the message defines whether the machine waits for a reply, as described in the [[user-guide-driver-fujinexim]] page.
## Remarks
None.
[onfujineximrequest_parameters]: ./images/onfujineximrequest_parameters.png
[onfujineximrequest_settings]: ./images/onfujineximrequest_settings.png