alias: user-guide-automation-task-mes-resourcebeginsetuprequest
tags:
- automation tasks
description: "Trigger task that listens for Begin Setup requests from the MES and starts the equipment-side handling for the Resource being set up"
---
# On Resource Begin Setup Request
:iot-system-event-lg:
This **trigger** task listens for Begin Setup requests coming from the MES and lets a workflow perform the equipment-side setup for the Resource that is being set up.
It belongs to the `System / MES` category, under `Triggers`, and is available in both Data Flow and Control Flow workflows. In a Control Flow workflow it appears as a `Start` trigger named `When a Resource performs Begin Setup`.

## Details
| Fields | Details |
| ----------------- | ---------------------------------------------------------------------------------- |
| Scope | Connect IoT
Data Platform
Enterprise Integration
Factory Automation |
| Workflow | Data flow
Control flow |
| `IsProtocol` flag | :material-close:{style="color:#EF5350"} |
## Behavior
When an operator performs [[user-guide-begin-setup]] on a Resource, the MES sends a request on the `ConnectIoT.BeginSetup.RequestReply` subject and waits for a reply. This task receives that request, emits the `resource` that is being set up, and emits `Success`.
The MES stays blocked until a reply is sent. If none is sent within the `Reply Timeout`, the task emits `Error` and the Begin Setup fails on the MES side.
The reply is produced differently depending on the workflow type:
- **Control Flow** - the reply is the result of the trigger's handler branch.
- **Data Flow** - a downstream [Send Resource Begin Setup Reply](task_resource_begin_setup_reply.md) task sends the reply.
## Inputs
| Name | Data Type | Description |
| -------------- | --------- | --------------------------------------------------------------------------------------------------------------------- |
| Enable/Disable | `Boolean` | Enables (`true`) or disables (`false`) the message listener at runtime. Works together with the `Auto Enable` setting. |
## Outputs
| Name | Data Type | Description |
| -------- | ---------- | ---------------------------------------------------- |
| resource | `Resource` | The Resource that is performing Begin Setup. |
| Success | `Boolean` | Triggered when a request is received and processed. |
| Error | `Error` | Triggered when the task fails or the reply times out.|
## Settings
On the `General` tab, you have the usual settings and the following settings:
| Name | Data Type | Values | Default | Description |
| ------------------------------------ | --------- | ------ | ------------------------------------ | ----------------------------------------------------------------------------------------------- |
| Auto Enable | `Boolean` | | `true` | Automatically enables the message listener when the task starts. |
| Reply Timeout | `Integer` | ms | `60000` | Amount of time allowed to wait for a reply before issuing a timeout. This setting is mandatory. |
| Resource Begin Setup Request Subject | `String` | | `ConnectIoT.BeginSetup.RequestReply` | Subject used to communicate with the MES. This setting is read-only. |

## Remarks
This task pairs with the [Send Resource Begin Setup Reply](task_resource_begin_setup_reply.md) task, which sends the reply back to the originating request.
This task uses a specific structure of context-based data called `zone`. More information on this topic can be read in the [Zones](../zones.md) page.