How should activate Line Control Interceptor instance: None - No instance will be used OnePerEnterprise - One Instance for all Lines (Enterprise level) OnePerSite - One Instance for all Lines (Site level) OnePerLine - One Instance per Line
callbackPort
Integer
0
What port to use to receive events from Printer Control. Use 0 to use a free port at callbackBasePort + 800
replyTimeout
Integer
60000
Number of milliseconds to wait for a Printer Control Request reply
registerMode
Enum
UnregisterFirst
UnregisterFirstJustRegister
Mode to register callbacks UnregisterFirst - Unregister Services before register new one to avoid duplicates JustRegister - Doesn't try to unregister anything prior. Can have duplicates.
Called in case of a download recipe for an ASM Pick and Place machine. The MES has to reply within a certain amount of time if the recipe validation is a pass or a fail. If no reply is given in time it will send a fail.
Called in case of a download recipe for an ASM Dek Printer machine. The MES has to reply within a certain amount of time if the recipe validation is a pass or a fail. If no reply is given in time it will send a fail.
Called in case of a download recipe for an ASM Process Lens machine. The MES has to reply within a certain amount of time if the recipe validation is a pass or a fail. If no reply is given in time it will send a fail.