Skip to content

Execute Cfx Command#

This Task is specific to be used with the IPC-CFX Driver.

This Task executes command CFX messages of a specific type (which can be configured in the Task's settings) and waits for the reply.

executecfxcommand_parameters

Inputs#

Name Data Type Description
Activate Boolean Activates the task

Outputs#

Name Data Type Description
Success Boolean If there was no problem emits a true
Error Error Error that occurred during the processing of this task

Settings#

On the General Tab, you have the usual settings and the following settings:

Name Data Type Values Default Description
Execution Mode enum Publish
SendRequest
Publish Execution Mode
Execution Destination enum Exchange
MessageSource
TargetHandle
Exchange Execution Destination
Clear Inputs (on activate) Boolean true Defines if it is to clear the input values after receiving an activate
Message Full Name string Name of the complete CFX message with the namespace included, e.g. 'CFX.Production.ActivitiesExecuted'.
Message enum StationStateChanged Specifies the behavior of the task

executecfxcommand_settings

Behavior#

When activated, this Task executes a command of a specific CFX message and waits for the reply.

After receiving the reply, this Task's outputs are updated.

Remarks#

None.