--- alias: user-guide-automation-task-oib-equipmentandsetup tags: - automation tasks description: "This task configures equipment data retrieval, including heads, feeders, and DP information" --- # Equipment and Setup Configuration The `Equipment and Setup Configuration` task is responsible for requesting the data for 3 requests: - PlaceHeads : The list of heads to be attached and detached from stations; - TapeFeeders : The list of feeders present in each station; - DPAxis : The list of DP's with information regarding the DP like for example the 'HeadSegmentActivation' If received, the requested data is sent as the proper output. ![1562171137862](./images/equipment_setup_parameters.png) ## Inputs | Name | Data Type | Description | |----------|-----------|--------------------------------------------------------------| | Activate | `Any` | Activate the task | | lineName | `String` | Optional. If not defined, command will be sent to all lines. | ## Outputs | Name | Data Type | Description | |-------------|-----------|--------------------------------------------------| | placeHeads | `Object` | The output for the Place Heads Event | | tapeFeeders | `Object` | The output for the Tape Feeders Event | | dpAxis | `Object` | The output for the DP Axis Event | | Success | `Boolean` | Triggered when the task is executed with success | | Error | `Error` | Triggered when the task failed for some reason | ## Settings On the `General` tab, you have the usual settings and the following settings: | Name | Data Type | Values | Default | Description | | ------------- | --------- | ------ | ------- | ------------------------------------------------------------ | | Auto Enable | `Boolean` | | `false` | If the task should automatically register event listening at startup or only when activated. | | Keep Alive | `Integer` | | `0` | Interval (in minutes) to issue a command to force retrieval of data. Set to 0 to disable. | ![1562259678207](./images/equipment_setup_settings.png) ## Behavior The task should be activated to request the information or if the settings auto enabled is set to true the task will start automatically. For the output of a specific data, just use the proper output to read the received data. ## Remarks None.