--- alias: user-guide-spc-nelson2 description: "This documentation details a rule definition using nine points for scope resolution" --- # Nelson 2 ## Rule definition 9 consecutive points on the same side of the centerline (similar to [WesternElectric4](spc_we4.md) with 9 points instead of 8/). ## Rule Scope | Indicator Scope | Scope Type | Chart Type | Chart | |-----------------|------------|------------|-------| | Indicator1And2 | All | | | Table: Nelson 2 configuration used for scope resolution ## Visual examples ### Indicator 1, point 1 ![Nelson 2 - Indicator 1 - Point 1][N2_WE4_indicator1_v1] ### Indicator 1, point 2 ![Nelson 2 - Indicator 1 - Point 2][N2_WE4_indicator1_v2] ### Indicator 2, Upper, point 1 ![Nelson 2 - Indicator 2 - Upper - Point 1][N2_WE4_indicator2_upper_v1] ### Indicator 2, Upper, point 2 ![Nelson 2 - Indicator 2 - Upper - Point 2][N2_WE4_indicator2_upper_v2] ### Indicator 2, Lower, point 1 ![Nelson 2 - Indicator 2 - Lower - Point 1][N2_WE4_indicator2_down_v1] ### Indicator 2, Lower, point 2 ![Nelson 2 - Indicator 2 - Lower - Point 2][N2_WE4_indicator2_down_v2] [N2_WE4_indicator1_v1]: images/N2_WE4_indicator1_v1.png [N2_WE4_indicator1_v2]: images/N2_WE4_indicator1_v2.png [N2_WE4_indicator2_upper_v1]: images/N2_WE4_indicator2_upper_v1.png [N2_WE4_indicator2_upper_v2]: images/N2_WE4_indicator2_upper_v2.png [N2_WE4_indicator2_down_v1]: images/N2_WE4_indicator2_down_v1.png [N2_WE4_indicator2_down_v2]: images/N2_WE4_indicator2_down_v2.png