Data Collection#

Overview#

Data Collection stores process values supplied by the machine in the applicable MES Data Collection Instance. The machine may post one or more readings while a Material is in process.

The parameter structure is machine-specific. The <ParameterName> is used only to illustrate the pattern; production nodes must use the actual MES Parameter names.

Choose the appropriate data path

Use Data Collection for values that are relevant to process execution, quality, traceability, or MES decision-making, such as measurements, inspection results, and process outcomes. It is not intended to store every sample from fast-changing machine signals.

When high-frequency or time-series machine data must be retained for diagnostics, trending, or analytics, publish it through an appropriate process-data mechanism, such as the Critical Manufacturing Data Platform ↗. Store only the process-relevant results or summaries in the MES Data Collection Instance.

Nodes#

Relative node OPC UA type Direction Purpose
DataCollection.Material.Name String Machine → MES Material to which the values belong
DataCollection.PostDataReadingNumber Int32 Machine → MES Reading number; the first reading normally uses 1
DataCollection.PostDataSampleId String Machine → MES Optional sample or correlation identifier. Default is empty string
DataCollection.Parameters.<ParameterName> Parameter-specific Machine → MES Actual process value
DataCollection.MachinePostDataRequest Boolean Machine → MES Requests that the current values be posted to MES
DataCollection.MESPostDataPerformed Boolean MES → Machine Confirms that the values were read, validated, and stored in MES

Parameter Tree Example#

DataCollection
├── Material
│   └── Name
├── MachinePostDataRequest
├── MESPostDataPerformed
├── PostDataReadingNumber
├── PostDataSampleId
└── Parameters
    ├── ActualCycleTime
    ├── AppliedTorque
    └── InspectionResult

Communication Flow#

sequenceDiagram
    autonumber
    participant M as Machine / OPC UA Server
    participant I as Connect IoT
    participant E as Critical Manufacturing MES

    M->>M: Write Material, reading, sample, and values
    M->>I: MachinePostDataRequest = true
    I->>E: Request Data Collection Instance Parameters for the Material
    E-->>I: Provide the resolved parameters

    loop Each required Parameter
        I->>M: Read configured Parameter node
        M-->>I: OPC UA value and status
        I->>I: Convert configured data type
    end

    I->>E: Post reading values

    alt MES post succeeds
        E-->>I: Data stored confirmation
        I->>M: MESPostDataPerformed = true
        M->>I: MachinePostDataRequest = false
        I->>M: MESPostDataPerformed = false
    else Validation or post fails
        E-->>I: Failure
        I-->>I: Record diagnostic, performed remains false
    end

Step-by-Step Process#

  1. During Track In, MES resolves MaterialDataCollectionContext.
  2. When the context returns a valid LongRunning Data Collection, MES creates and keeps the Data Collection Instance open for the in-process Material.
  3. The machine writes every required value below DataCollection.Parameters.
  4. The machine writes the Material name, reading number, and optional sample identifier.
  5. After all payload values are stable, the machine sets MachinePostDataRequest = true.
  6. Connect IoT validates the Resource and resolves the Material. If the name is empty, FIFO is permitted only when IndEqAutomationOperationAllowFIFO = true.
  7. MES resolves the open Data Collection Instance and the Parameters expected for that reading.
  8. Connect IoT reads each node by its exact Parameter name, validates the OPC UA read status, and converts the value according to IndEqOpcUaParameterDataType.
  9. MES validates mandatory values, limits, and reading rules, and then stores the reading.
  10. Connect IoT sets MESPostDataPerformed = true only after MES stores the values successfully.
  11. The machine resets MachinePostDataRequest, after which Connect IoT resets MESPostDataPerformed.

Reading and Sample Rules#

  • The first reading normally has number 1.
  • Subsequent readings increment according to the Data Collection definition.
  • The reading number must be within the configured range.
  • PostDataSampleId is optional.
  • Reuse of a reading number or sample identifier must follow the configured MES Data Collection behavior and must be verified during commissioning.

No-Data and Parse Failures#

The request fails when the machine provides no expected values or the returned values cannot be parsed. The diagnostic should indicate that the machine supplied no data to be posted or that parsing failed. MESPostDataPerformed remains false.

Diagnostics should include:

  • Resource and Material values.
  • the Data Collection definition and the applicable sample and reading ranges.
  • the Parameter name, resolved OPC UA node, configured IndEqOpcUaParameterDataType, and actual OPC UA data type.

Validation and Assumptions#

  • Actual machine Parameter names match MES Parameter names.
  • Each supported data type converts correctly.
  • Missing mandatory values fail before MESPostDataPerformed is set.
  • Invalid reading numbers and closed/missing instances are rejected.
  • Multiple readings are stored under the correct reading number.
  • Handshake reset allows a later request to be detected again.
  • Resource is set as EnableAutomationScenarios = true
  • MES automation controller type is IndEqController