Skip to content

Recipe Download#

Overview#

Recipe Download transfers the process settings resolved by MES to the machine during Track In. The standard defines where parameters are written, but it does not prescribe the process-specific parameter names.

Recipe.<ParameterName> is a placeholder. A real machine uses actual names such as ProductCode, TargetSpeed, TemperatureSetpoint, or TorqueTarget.

Node Mapping#

Root recipe parameters use:

<BaseNodeId>.Recipe.<ParameterName>

Sub-recipe parameters use:

<BaseNodeId>.Recipe.<ResourceRecipeName>.<ParameterName>

Example:

Recipe
├── ProductCode
├── TargetSpeed
└── Tightening
    ├── TorqueTarget
    └── AngleTarget
MES artifact OPC UA segment Rule
Main recipe Parameter name <ParameterName> Exact, case-sensitive match with the machine node Tag Name
Sub-recipe display name <ResourceRecipeName> Exact match with the OPC UA Folder Name
Sub-recipe Parameter name <ParameterName> Exact match below the sub-recipe folder
IndEqOpcUaParameterDataType OPC UA value type Must exist in IndEqOpcUaDataTypes and be compatible with the target node

Communication Flow#

sequenceDiagram
    autonumber
    participant E as Critical Manufacturing MES
    participant I as Connect IoT
    participant S as OPC UA Server

    E->>E: Perform Track In within transaction and resolve RecipeContext
    E->>E: Build main and sub-recipe parameter set
    E-->>I: Parameter names, hierarchy, values, and data types

    loop Each recipe parameter
        I->>I: Build relative node path
        I->>I: Validate and convert to the OPC UA data type
        I->>S: Write recipe value
        S-->>I: Write status
    end

    alt All required writes succeed
        I-->>E: Recipe download succeeded, continue Track In handshake
    else A required write fails
        I-->>E: Recipe download failed with node diagnostic
    end

Step-by-Step Process#

  1. Track In is initiated either by the machine or by the operator.
  2. MES verifies that Recipe Management Enabled is enabled for the Resource.
  3. MES resolves RecipeContext and selects the Recipe and respective Sub-recipes, if applicable.
  4. Connect IoT receives the Parameter names, values, hierarchy, and configured OPC UA data types.
  5. For each main Parameter, Connect IoT builds Recipe.<ParameterName>.
  6. For each Sub-recipe Parameter, it builds Recipe.<ResourceRecipeName>.<ParameterName>.
  7. Connect IoT writes each OPC UA node and checks the returned write status.
  8. Connect IoT issues the Track In performed signal only after every required Parameter has been written successfully.
  9. The machine confirms the performed signal within MachineReplyTimeout; MES commits Track In only after that confirmation.

Configuration Requirements#

  • Resource Recipe Management Enabled is enabled.
  • RecipeContext resolves a valid recipe.
  • Recipe Parameter names, sub-recipe display names, and sub-recipe Parameter names match the OPC UA structure exactly.
  • EnableAutomationScenarios is set to true.

Validation and Assumptions#

  • Main recipe parameters are written to the correct nodes.
  • Sub-recipe folders and parameters resolve correctly.
  • A missing or non-writable required node causes a clear failure.
  • Operator-initiated Track In also downloads the recipe when enabled.