Configuring Alarm Management Behavior#
Equipment Integration is designed to be able to trigger a set of behaviors when an Alarm occurs.
How it works#
The configuration is done by configuring the Smart Table SemiAlarmManagement.
Notifications are triggered based on the context defined on the Smart Table columns:
- Alarm Id:
- Id of the Alarm on the Tool, corresponds to ALID on SECS/GEM communication.
- Alarm State:
- State of the Alarm, if the Alarm is being Set or Cleared:
- Alarm Set True corresponds to Alarm Set
- Alarm Set False corresponds to Alarm Cleared
- State of the Alarm, if the Alarm is being Set or Cleared:
- AutomationController:
- Automation Controller connected to the Automation Controller Instance that has triggered the Alarm.
- This setting can be use to set a particular behavior for all Equipment running the same Automation Controller
- Automation Controller connected to the Automation Controller Instance that has triggered the Alarm.
- Resource:
- Resource connected to the Automation Controller Instance.
If no line matches the context no action will be triggered.
Behavior is defined by filling the following values:
- ErrorType:
- Type of the Error, defines Error Handling Action to be taken.
- Error handling behavior can be set by following this document.
- Store Data Collection:
- If enabled, an Immediate Data Collection Instance will be posted to the Resource containing the information of the Alarm.
- Include Materials In Process:
- If enabled, Materials currently In Process on the Resource will be set as context for the Error Handling actions, allowing for actions to be taken on them.
- Automation Module Name:
- Automation Module Name Attribute value for the Sub-Resource affected by the Alarm, if known, this will be added to the Error Handling context.
- Context:
- Addtional Context for Error Handling actions, this field expected a valid JSON Object.
Notes and Requirements#
Note
*For this to be triggered Alarms must be enabled on the tool, this can be accomplished be enabling all or specific alarms. * Error Handling is also configurable and additional Error Types can be added if needed.
Example of configuring a Notification#
Below you can find an example on how to setup a Notification: