Work Started#
Overview#
This feature enables MES recipe management for IPC-CFX equipments.
How To Configure#
Relevant Artifacts#
The table below describes the properties for this entity type:
| Name | Type | Is Mandatory | Data Type | Description |
|---|---|---|---|---|
| IoTMetadataDefinition | SmartTable | Yes | Metadata configuration for equipment integration | |
| IoTCreateNewRecipe | DEE | Yes | Create or update a recipe |
IoTMetadataDefinition Resource Level Configuration#
At the Resource level, there are several configuration we can make to set this feature.
| Resource | Resource Type | Area | Name | Value | Description |
|---|---|---|---|---|---|
| MES IPC-CFX Resource | useIPCCFXtoRecipeActivated | true | Enable recipe management for the current Resource. |
How It Works#
The equipment sends a CFX.Production.RecipeActivated Event from IPC-CFX standard.
In the Event message we will retrieve the Recipe Name, Revision and Resource Lane, which we will use to set the recipe for the correct Resource/Lane in MES using DEE IoTCreateNewRecipe.
CFX RecipeActivated Example
{
"RecipeName": "RECIPE1234",
"Revision": "A",
"Lane": 1,
"Stage": null,
"ExpectedCycleTime": 60,
"ExpectedUnitsPerWorkTransaction": 1,
"NumberOfComponentsPerUnit": 500,
"WorkOrderIdentifier": {
"WorkOrderId": "WO-1000-1000",
"Batch": "WO-1000-1000-B1"
},
"TargetQuantity": 500.0,
"RelevantSurface": "PrimarySurface",
"RecipeStagesInformationā: [
{
"Stage": {
"StageSequence": 1,
"StageName": "STAGE1",
"StageType": "Work"
}
"ExpectedCycleTime": 80,
"NumberOfComponentsPerUnit": 200
},
{
"Stage": {
"StageSequence": 2,
"StageName": "STAGE2",
"StageType": "Work"
}
"ExpectedCycleTime": 120,
"NumberOfComponentsPerUnit": 250
}
]
}