Setup PanaCIM#
The features handled in this integration have as base PanaCIM v8831 specification.
Overview#
This feature is responsible for handling the connection to PanaCIM equipment and general behavior configuration.
How To Configure#
You can configure the Host Port, Address and what Lines from which we can process the events.
Relevant Artifacts#
The table below describes the properties for this entity type:
| Name | Type | Is Mandatory | Data Type | Description |
|---|---|---|---|---|
| IoTMetadataDefinition | SmartTable | Yes | Metadata configuration for equipment integration |
How It Works#
You can set in IoTMetadataDefinition the appropriate values for your setup.
Every time you change Setup values in IoTMetadataDefinition you must restart the Automation Controller.
IoTMetadataDefinition Area Level Configuration#
IoT Metadata Definition is configured with the following:
| Resource | Resource Type | Area | Name | Value | Description |
|---|---|---|---|---|---|
| PanaCIM Line Area | PanaCIM_port | Host Ip Port | Port where PanaCIM Interface is listening | ||
| PanaCIM Line Area | PanaCIM_address | Host Ip Address | Address where PanaCIM Interface is listening | ||
| PanaCIM Line Area | Panacim_LinesToHandle | Line Name | Name of the Line from which we will handle events | ||
| PanaCIM Line Area | isToAlwaysReplyOk | true/false | Bypass the Processing results and always reply with Success | ||
| PanaCIM Line Area | Panacim_LineNameStationName_(Line Name)_(Station Name) | MES Resource Name | Relation between MES Resource name and PanaCIM Names |
isToAlwaysReplyOk is a developer configuration, whe will always reply to the PanaCIM request with "Success", this will enable us to act as a listener, gathering all the information needed for integration without impacting normal process.